Blood Donation Research - Blood Types, Blood Group, Leukemia, Red Cross

Blood Donation Research Today is a free monthly online journal that collates and summarizes the latest research about Blood Donation, including details on blood types, blood group, leukemia, red cross.


Blood Donation Research Today

Home

View Latest Issue

Information About Blood Donation

Books on Blood Donation

Advertising in Research Today

View Other Research Today Publications



Evaluation of a new enzyme-linked immunosorbent assay for detection of Chagas antibody in US blood donors.

Tobler LH, Contestable P, Pitina L, Groth H, Shaffer S, Blackburn GR, Warren H, Lee SR, Busch MP

Blood Systems Research Institute, San Francisco, California 94118, USA. ltobler@bloodsystems.org

BACKGROUND: Chagas disease, caused by the parasite Trypanosoma cruzi, represents a serious blood safety problem due to increasing immigration from Latin America. The Food and Drug Administration recently recommended implementation of Chagas antibody screening for US donors as soon as a suitable assay is licensed. An anonymized preclinical study of a prototype T. cruzi lysate-based enzyme-linked immunosorbent assay (ELISA) developed by Ortho-Clinical Diagnostics was conducted. STUDY DESIGN AND METHODS: Two populations of specimens were evaluated: 1) 10,192 sequential donations from blood donors residing in the El Paso, Texas, area and 2) 178 specimens from South America which were presumptively positive for antibodies to T. cruzi and purchased from commercial vendors. RESULTS: A total of 10,189 (99.97%) of the 10,192 screened donor specimens did not react, whereas 3 (0.03%) tested initially reactive. The 3 initially reactive specimens tested repeat reactive and were confirmed by radioimmunoprecipitation analysis (RIPA). Based on antibody profile analysis, 2 of the 3 Chagas-positive specimens were from the same donor. Observed specificity of the test was therefore 100 percent. Of the specimens from South America, 173 of 178 were reactive by the prototype ELISA. Of the 5 nonreactive specimens, all did not react by indirect fluorescence assay, but 4 were positive by RIPA. Therefore, calculated sensitivity of the ELISA was 97.7 percent (173/177). CONCLUSIONS: These studies indicate that the prototype ELISA has excellent sensitivity and specificity for detection of antibodies to T. cruzi in donors. Moreover, among donations from a geographically selected collection region of the United States, observed seroprevalence was 0.03 percent.

Published 8 January 2007 in Transfusion, 47(1): 90-6.
Full-text of this article is available online (may require subscription).

Place a permanent text-link or advertisement here for just US$15.

© 2005-2008 Blood Donation Research Today. All Rights Reserved.



Blood Donation Research Today Archive:

Volume 1 (2005)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 2 (2006)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 3 (2007)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 4 (2008)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)



Blood Donation Books

Blood, Plasma and Plasma Proteins: A Unique Contribution to Modern Healthcare

Blood, Plasma and Plasma Proteins: A Unique Contribution to Modern Healthcare